Introducing the new icountLCM ‘Classic’There is a new addition to the proven range – the icountLCM ‘Classic’. Only available from Parker, the ‘Classic
DEFSTAN 91-91 Issue 6 Jet A-1Fuel Specification, adopts particle counting.The first fully functional particle counter approved for use on aviation fue
The Parker icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in Aviation Turbine and othe
icountACM20 - rear viewOrdering InformationStandard products table - icount ACM20icountACM20 Lab UnitSpecificationsInput Power Socket (note that you w
For use in explosive and hazardous areasicountACM20Z is designed to be used to monitor various fuels from existing sampling points in hazardous locati
Construction: Unit: Stainless Steel Carrying case: ABS Hand-held display: ABS Keypad: polyester membrane Mechanical components: Brass, plated steel, s
icountACM20ZATEX Approved Portable Particle CounterInstallation Details12Online Commission Kita – icountACM20 Zone II Particle Counterb – Battery C
Ideal for batch oil samplingThe UBS provides the dynamic link to portable particle counters. The UBS off-line sampler has microprocessor technology to
3.15 (80mm) CTRS4.72 (120mm) CTRS12.6 (319mm)6.5 (165mm)5.79 (147mm)7.05 (179mm)5.94 (151mm).433 (11mm)3.94 (100mm) CTRSInstallation DetailsUniversal
Bottle CleanlinessIt is preferable that bottles have sealing screw caps and both parts are cleaned to a suitable level in accordance with ISO3722.Stan
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PR
Universal Bottle SamplerOrdering Information16Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Not
icountBS - Bottle SamplerThe benchtop solution to fl uid contaminationbottle sampling17
The Complete Solution - Industrial Design Combined with State of the Art Technology18The icountBS - Bottle Sampler from Parker, with its innovative in
Home Screen Sample ID Input Number of Sample RunsSample Volume Flush Volume Start Test19
Analyzing the Test ResultsOnce the automatic oil sample test has been completed, what next?Solid contaminants in uid power systems vary in size, sha
icountBS Product Specifi cationPrinciple of Operation Laser based light obscurationDimensions H=20.9” x W=7.48” (8.27” Door) x D=16.1”Weight 31 lb. (14
icountBS - Bottle Sampler Ordering Information22Part NumberIBS3000 (of ine/online)IBS3100 (of ine only)Accessories Part Number Included250ml Sample
The effective link to ensure accurate contamination monitoringThe SPS (Single Point Sampler) is a lightweight, compact and easy to use online sampling
Connection InstructionsSingle Point Sampler Features & BenefitsThe Single Point Sampler provides a means to connect an icountLCM20 to a single pre
Fluid Compatibility:Mineral oil and petroleum based fluidsPhosphate ester fluidFor other fluids consult factorySeals:Fluorocarbon or Perfluoroelastome
icountLCM20 Contamination Monitor... 1icountACM20 Lab Unit and icountACM20Z...
Effective in-line system sensors and monitorsIn-line System20 sensors and hand-held monitors designed to give accurate and instant uid system readin
System20Features & BenefitsTypical Applications Drilling equipment Mining Grinding and conveying Industrial hydraulics Mobile applicationsHydrau
Construction:Industrial: (STI)Body: 303 SSInternal components: SS and BrassMobile: (STS)Body: 303 SSInternal components: Cast Aluminium and SSFlow Cap
System20Electronic Monitor SpecificationOrdering InformationConstruction:A sealed assembly requiring no routine maintenance or adjustment. Body moldin
System20Analog MonitorOrdering InformationConstruction:A sealed assembly requiring no routine maintenance or adjustment. Body moulding in ABS. The mon
icountPDOnline Particle Detector31
icountPDThe icountPD from Parker represents the most up-to-date technology in solid particle detection.The design dynamics, attention to detail, and s
icountPD/icountPDR/icountPDZDiagnostic self check start-up time 5 secondsMeasurement period 5 to 180 secondsReporting interval through RS232 0 to 3
icountPDDimensions / Installation Details1.9”(49)0.6”(16)1.5”(37)3.4”(86)2.4” CTRS(60 CTRS)4.3”(110)7.2”(182)6.1”(155)2.0”(52)0.8”(21)2 mounting locat
icountPDVariable mA Output SettingsThe following table can be used to equate the analog output for channels A, B, and C independently.Example: ISO co
IntroductionParker Hannifi n is comprised of eight global groups: Aerospace, Climate & Industrial Controls, Fluid Connectors, Seal, Hydraulics, Fil
icountPDDigital display indicationThe digital display will show the actual measured codes, the channel (µ) size and the user defineable limits. Visib
This simple to use ow control device ts on the downstream (outlet) side of the icountPD and is tted with a differential pressure valve that adju
For use in explosive and hazardous areasThe icountPD Particle Detector from Parker represents the most up to date technology in solid particle contami
Notes:1. When “3” is selected in Box 2, “1” must be selected in Box 7.2. Aviation Fuel option can also be used for diesel uids.3. For iPD and
Notes40
41icount Oil Sampler (IOS)Portable Condition Monitoring for HydraulicOil and Fuel Systems
42Accurate Condition Monitoring madeQuick, Simple and Cost EffectiveThe icountOS (IOS) is an innovative solution to the challenge of measuring the qua
43Wherever, Whenever you need to be100% sure of Oil and Fuel QualityWith its robust carrying case, sealed to IP67, and proven laser and diagnostics te
44icountOSHow It WorksHydraulic CircuitOUTPUT350 barmax.inputpressure(Optional)Pump0.3 barCheck Valve10 barCheck ValveFlowcell2.5 bar max.input pressu
45icountOSTo remove the PRV, press down on the removal tool at the same time as lifting PRV off.Attach OUTLET (Ø 4mm) hose(High pressure is de ned fo
A portable particle counter designed to be used in the fi eldicountLCM20 is a proven answer to uid system contamination monitoring. Multi-standard IS
46High Onboard Test Data Storage CapacityClass leading onboard memory provides storage capacity for up to 250,000 sets of test results. Data is displa
47Quick ConnectionConnecting the IOS is quick and reliable. The uid connectors are on the front panel, with two secure push ttings: .236” diameter
48The IOS is a unique product in that it has its own web page generator which means that the stored data can be downloaded or viewed on any PC or lapt
49Key1. The Unit Status page is a list of current values for various parameters for the connected IOS unit.Unit Status PageKey1. Alarm lim
50icountOSSpecificationsFeature Specifi cationProduct start-up time 10 seconds minimumMeasurement period Default 30 seconds run time; 15 seconds data l
51icountOSHow To OrderKey Fluid Type Calibration Connection OptionsIOS1220EUR Mineral MTD Online No optionsIOS1210EUR Mineral MTD Of ine No options K
Fast, reliable and accurate inline detection of moisture in fl uidsMS moisture sensors provide fast, reliable and accurate inline detection of moisture
icountMS RangeFeatures and BenefitsTypical Applications Ground support vehicles Pulp and paper plants Marine hydraulics Power transmission & di
Installation Details% Saturation Calibration Accuracy: +3% RHTemperature Calibration Accuracy: ±1°CThermal Stability: ±1% RH (over compensated
Pressure:(MAOP): 6,000 PSI (420 bar)Operating temperature:Minimum: -40°F (-40°C) - dependent on seal materialMaximum: +185°F (+85°C)Flow through senso
icountLCM20Features & BenefitsTest time: 2 minutesParticle counts: MTD 4+, 6+, 14+, 21+, 38+ and 70+ microns(c)ACFTD 2+, 5+, 15+, 25+, 50+ and 1
Moisture sensor output settingThe Moisture sensor reports on the saturation levels of the fluid passing through the sensing cell. The output is a line
Ordering Information57Key Model Fluid Type Output Options Thread Forms Connector Future OptionMS 2 Programmable 2 Mineral 01 0 -3 Vdc 1 G 1/4” BSP Bon
Portable and battery powered for ‘go-anywhere’ monitoringHand-held condition monitor provides a visual comparison between new and used oilsParker’s Oi
OilcheckFeatures & BenefitsTypical Applications Fleet Maintenance Garages Construction equipment maintenance Plant maintenanceThe Oilcheck from
Case construction:ABSCircuitry:Microprocessor controlBattery:1 x 9V alkaline (supplied)Display:LCDSuitable oil types:Mineral and synthetic based oilsR
KittiwakeCondition Monitoring Products61
ANALEXfdMplus in remote locations where full laboratory analysis is not possible.Samples may be presented for measurement using a variety of sample ap
DIGI Field KitInsolubles (soot)Monitor combustion related debris and oxidation products.High insolubles will cause varnish formation on hot surfaces,
Low Range DIGI Water KitReagents, Spares and ConsumablesTest kits for individual parameters contain reagents, consumables and full instructions for mu
Heated Viscometer most important characteristic. It is the viscosity that gives the oil’s resistance to ow and the strength of the oil lm between
Automatic Particle Counters (APC), have been widely used for many years in condition monitoring of hydraulic fluids. However, it is only recently that
MHC Bearing Checker Easy to Use and Interpret for Quick AnalysisSimply attach the unit via the magnetic sensor head and within 10 seconds both dB Leve
67Guide to Contamination StandardsThis guidebook is aimed at engineers, technicians and quality control personnel involved in contamination control. I
68ISO Cleanliness CodeHydraulic Fluid ContaminationISO code numberNumber of particles per mlMore than Up to and including22 20,000 40,00021 10,000 20,
69ISO code numbersType of systemTypical componentsSensitivity23 / 21 / 17 Low pressure systems with large clearances Ram pumps Low20 / 18 / 15 Typical
70The NAS 1638 cleanliness standard was developed for aerospace components in the US andis still widely used for industrial and aerospace uid power
71Note that this standard is technically identical to ISO 11218.Maximum contamination limits (particles per ml)MTD >4μm(c) >6μm(c) >14μm(c) &
72The GOST standard is developed by the Technical Committee of Standardization TK 184 “Ensuring Industrial Cleanliness” introduced by the Government o
73The Navy Standard for Hydraulic Fluids used for aircraft hydraulic systems is de ned in the Aviation Hydraulics Manual (1989), Table 2-1, Navy Stan
74Percent contamination vs. PPM (parts per million)Percent PPM100% 1,000,00010% 100,0001% 10,0000.1% 1,0000.01% 1000.001% 10Volume1 litre = 1 000 ml1
The items described in this document and other documents and descriptions provided by Parker Hanni n Corporation, its subsidiaries and its authorized
*Note: In compliance with international standards, all Parker portable particle counters can meet the ISO Medium test dust standards. The icountLCM’s,
Offer of SaleThe items described in this document and other documents and descriptions provided by Parker Hanni n Corporation, its subsidiaries and i
Notes
Notes
The Aerospace Group is a leader in the development, design, manufacture and servicing of control systems and components for aerospace and related high
North AmericaCompressed Air TreatmentFiltration & Separation/BalstonHaverhill, MA978 858 0505www.parker.com/balstonFinite Airtek Filtration Airtek
icountLCM20Portable Particle CounterWhy On-Site Fluid Contamination Monitoring?Data Download ManagementDedicated software, provides the link between a
Kommentare zu diesen Handbüchern