MTD 136-495A Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Rasenmäher MTD 136-495A herunter. MTD 136-495A Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Condition Monitoring
Products & Custom Solutions
Seitenansicht 0
1 2 3 4 5 6 ... 83 84

Inhaltsverzeichnis

Seite 1 - Condition Monitoring

Condition MonitoringProducts & Custom Solutions

Seite 2 - Legal Notifi cations

Introducing the new icountLCM ‘Classic’There is a new addition to the proven range – the icountLCM ‘Classic’. Only available from Parker, the ‘Classic

Seite 3

DEFSTAN 91-91 Issue 6 Jet A-1Fuel Specification, adopts particle counting.The first fully functional particle counter approved for use on aviation fue

Seite 4 - Introduction

The Parker icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in Aviation Turbine and othe

Seite 5 - Fluid Condition Monitoring

icountACM20 - rear viewOrdering InformationStandard products table - icount ACM20icountACM20 Lab UnitSpecificationsInput Power Socket (note that you w

Seite 6

For use in explosive and hazardous areasicountACM20Z is designed to be used to monitor various fuels from existing sampling points in hazardous locati

Seite 7

Construction: Unit: Stainless Steel Carrying case: ABS Hand-held display: ABS Keypad: polyester membrane Mechanical components: Brass, plated steel, s

Seite 8 - Specification

icountACM20ZATEX Approved Portable Particle CounterInstallation Details12Online Commission Kita – icountACM20 Zone II Particle Counterb – Battery C

Seite 9 - Data Download Management

Ideal for batch oil samplingThe UBS provides the dynamic link to portable particle counters. The UBS off-line sampler has microprocessor technology to

Seite 10

3.15 (80mm) CTRS4.72 (120mm) CTRS12.6 (319mm)6.5 (165mm)5.79 (147mm)7.05 (179mm)5.94 (151mm).433 (11mm)3.94 (100mm) CTRSInstallation DetailsUniversal

Seite 11 - Lab Unit

Bottle CleanlinessIt is preferable that bottles have sealing screw caps and both parts are cleaned to a suitable level in accordance with ISO3722.Stan

Seite 12 - Features & Benefits

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PR

Seite 13

Universal Bottle SamplerOrdering Information16Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Not

Seite 14 - Product Features:

icountBS - Bottle SamplerThe benchtop solution to fl uid contaminationbottle sampling17

Seite 15 - Specifications

The Complete Solution - Industrial Design Combined with State of the Art Technology18The icountBS - Bottle Sampler from Parker, with its innovative in

Seite 16 - Online Commission Kit

Home Screen Sample ID Input Number of Sample RunsSample Volume Flush Volume Start Test19

Seite 17 - Universal Bottle Sampler

Analyzing the Test ResultsOnce the automatic oil sample test has been completed, what next?Solid contaminants in  uid power systems vary in size, sha

Seite 18

icountBS Product Specifi cationPrinciple of Operation Laser based light obscurationDimensions H=20.9” x W=7.48” (8.27” Door) x D=16.1”Weight 31 lb. (14

Seite 19

icountBS - Bottle Sampler Ordering Information22Part NumberIBS3000 (of ine/online)IBS3100 (of ine only)Accessories Part Number Included250ml Sample

Seite 20

The effective link to ensure accurate contamination monitoringThe SPS (Single Point Sampler) is a lightweight, compact and easy to use online sampling

Seite 21

Connection InstructionsSingle Point Sampler Features & BenefitsThe Single Point Sampler provides a means to connect an icountLCM20 to a single pre

Seite 22 - Art Technology

Fluid Compatibility:Mineral oil and petroleum based fluidsPhosphate ester fluidFor other fluids consult factorySeals:Fluorocarbon or Perfluoroelastome

Seite 23

icountLCM20 Contamination Monitor... 1icountACM20 Lab Unit and icountACM20Z...

Seite 24 - Analyzing the Test Results

Effective in-line system sensors and monitorsIn-line System20 sensors and hand-held monitors designed to give accurate and instant  uid system readin

Seite 25

System20Features & BenefitsTypical Applications Drilling equipment Mining Grinding and conveying Industrial hydraulics Mobile applicationsHydrau

Seite 26 - Information

Construction:Industrial: (STI)Body: 303 SSInternal components: SS and BrassMobile: (STS)Body: 303 SSInternal components: Cast Aluminium and SSFlow Cap

Seite 27 - Single Point Sampler

System20Electronic Monitor SpecificationOrdering InformationConstruction:A sealed assembly requiring no routine maintenance or adjustment. Body moldin

Seite 28

System20Analog MonitorOrdering InformationConstruction:A sealed assembly requiring no routine maintenance or adjustment. Body moulding in ABS. The mon

Seite 29

icountPDOnline Particle Detector31

Seite 30 - System20

icountPDThe icountPD from Parker represents the most up-to-date technology in solid particle detection.The design dynamics, attention to detail, and s

Seite 31

icountPD/icountPDR/icountPDZDiagnostic self check start-up time 5 secondsMeasurement period 5 to 180 secondsReporting interval through RS232 0 to 3

Seite 32

icountPDDimensions / Installation Details1.9”(49)0.6”(16)1.5”(37)3.4”(86)2.4” CTRS(60 CTRS)4.3”(110)7.2”(182)6.1”(155)2.0”(52)0.8”(21)2 mounting locat

Seite 33

icountPDVariable mA Output SettingsThe following table can be used to equate the analog output for channels A, B, and C independently.Example: ISO co

Seite 34

IntroductionParker Hannifi n is comprised of eight global groups: Aerospace, Climate & Industrial Controls, Fluid Connectors, Seal, Hydraulics, Fil

Seite 35 - Online Particle Detector

icountPDDigital display indicationThe digital display will show the actual measured codes, the channel (µ) size and the user defineable limits. Visib

Seite 36 - 3 Versions Available

This simple to use  ow control device  ts on the downstream (outlet) side of the icountPD and is  tted with a differential pressure valve that adju

Seite 37

For use in explosive and hazardous areasThe icountPD Particle Detector from Parker represents the most up to date technology in solid particle contami

Seite 38 - Maximum Torque 5Nm

Notes:1. When “3” is selected in Box 2, “1” must be selected in Box 7.2. Aviation Fuel option can also be used for diesel  uids.3. For iPD and

Seite 40

41icount Oil Sampler (IOS)Portable Condition Monitoring for HydraulicOil and Fuel Systems

Seite 41 - Auxiliary Flow Device

42Accurate Condition Monitoring madeQuick, Simple and Cost EffectiveThe icountOS (IOS) is an innovative solution to the challenge of measuring the qua

Seite 42 - For use in explosive

43Wherever, Whenever you need to be100% sure of Oil and Fuel QualityWith its robust carrying case, sealed to IP67, and proven laser and diagnostics te

Seite 43 - Ordering Information

44icountOSHow It WorksHydraulic CircuitOUTPUT350 barmax.inputpressure(Optional)Pump0.3 barCheck Valve10 barCheck ValveFlowcell2.5 bar max.input pressu

Seite 44

45icountOSTo remove the PRV, press down on the removal tool at the same time as lifting PRV off.Attach OUTLET (Ø 4mm) hose(High pressure is de ned fo

Seite 45 - Oil and Fuel Systems

A portable particle counter designed to be used in the fi eldicountLCM20 is a proven answer to  uid system contamination monitoring. Multi-standard IS

Seite 46

46High Onboard Test Data Storage CapacityClass leading onboard memory provides storage capacity for up to 250,000 sets of test results. Data is displa

Seite 47

47Quick ConnectionConnecting the IOS is quick and reliable. The  uid connectors are on the front panel, with two secure push  ttings: .236” diameter

Seite 48 - Detection Technology

48The IOS is a unique product in that it has its own web page generator which means that the stored data can be downloaded or viewed on any PC or lapt

Seite 49 - Low Pressure Connection Setup

49Key1. The Unit Status page is a list of current values for various parameters for the connected IOS unit.Unit Status PageKey1. Alarm lim

Seite 50

50icountOSSpecificationsFeature Specifi cationProduct start-up time 10 seconds minimumMeasurement period Default 30 seconds run time; 15 seconds data l

Seite 51 - Pressure Reducing Valve (PRV)

51icountOSHow To OrderKey Fluid Type Calibration Connection OptionsIOS1220EUR Mineral MTD Online No optionsIOS1210EUR Mineral MTD Of ine No options K

Seite 52 - Web Interface

Fast, reliable and accurate inline detection of moisture in fl uidsMS moisture sensors provide fast, reliable and accurate inline detection of moisture

Seite 53 - Set Report Standard Page

icountMS RangeFeatures and BenefitsTypical Applications Ground support vehicles Pulp and paper plants Marine hydraulics Power transmission & di

Seite 54

Installation Details% Saturation Calibration Accuracy: +3% RHTemperature Calibration Accuracy: ±1°CThermal Stability: ±1% RH (over compensated

Seite 55 - How To Order

Pressure:(MAOP): 6,000 PSI (420 bar)Operating temperature:Minimum: -40°F (-40°C) - dependent on seal materialMaximum: +185°F (+85°C)Flow through senso

Seite 56

icountLCM20Features & BenefitsTest time: 2 minutesParticle counts: MTD 4+, 6+, 14+, 21+, 38+ and 70+ microns(c)ACFTD 2+, 5+, 15+, 25+, 50+ and 1

Seite 57 - Features and Benefits

Moisture sensor output settingThe Moisture sensor reports on the saturation levels of the fluid passing through the sensing cell. The output is a line

Seite 58 - MS200 Moisture Sensor

Ordering Information57Key Model Fluid Type Output Options Thread Forms Connector Future OptionMS 2 Programmable 2 Mineral 01 0 -3 Vdc 1 G 1/4” BSP Bon

Seite 59 - MS300 Intrinsically Safe

Portable and battery powered for ‘go-anywhere’ monitoringHand-held condition monitor provides a visual comparison between new and used oilsParker’s Oi

Seite 60 - Moisture Sensor Displays

OilcheckFeatures & BenefitsTypical Applications Fleet Maintenance Garages Construction equipment maintenance Plant maintenanceThe Oilcheck from

Seite 61

Case construction:ABSCircuitry:Microprocessor controlBattery:1 x 9V alkaline (supplied)Display:LCDSuitable oil types:Mineral and synthetic based oilsR

Seite 62 - Oilcheck

KittiwakeCondition Monitoring Products61

Seite 63

ANALEXfdMplus in remote locations where full laboratory analysis is not possible.Samples may be presented for measurement using a variety of sample ap

Seite 64

DIGI Field KitInsolubles (soot)Monitor combustion related debris and oxidation products.High insolubles will cause varnish formation on hot surfaces,

Seite 65 - Kittiwake

Low Range DIGI Water KitReagents, Spares and ConsumablesTest kits for individual parameters contain reagents, consumables and full instructions for mu

Seite 66 - ANALEXfdMplus

Heated Viscometer most important characteristic. It is the viscosity that gives the oil’s resistance to  ow and the strength of the oil  lm between

Seite 67 - DIGI Field Kit

Automatic Particle Counters (APC), have been widely used for many years in condition monitoring of hydraulic fluids. However, it is only recently that

Seite 68 - Low Range DIGI Water Kit

MHC Bearing Checker Easy to Use and Interpret for Quick AnalysisSimply attach the unit via the magnetic sensor head and within 10 seconds both dB Leve

Seite 69 - Heated Viscometer

67Guide to Contamination StandardsThis guidebook is aimed at engineers, technicians and quality control personnel involved in contamination control. I

Seite 70 - MHC Bearing Checker

68ISO Cleanliness CodeHydraulic Fluid ContaminationISO code numberNumber of particles per mlMore than Up to and including22 20,000 40,00021 10,000 20,

Seite 71

69ISO code numbersType of systemTypical componentsSensitivity23 / 21 / 17 Low pressure systems with large clearances Ram pumps Low20 / 18 / 15 Typical

Seite 72 - ISO Cleanliness Code

70The NAS 1638 cleanliness standard was developed for aerospace components in the US andis still widely used for industrial and aerospace  uid power

Seite 73

71Note that this standard is technically identical to ISO 11218.Maximum contamination limits (particles per ml)MTD >4μm(c) >6μm(c) >14μm(c) &

Seite 74 - NAS 1638 Table

72The GOST standard is developed by the Technical Committee of Standardization TK 184 “Ensuring Industrial Cleanliness” introduced by the Government o

Seite 75 - SAE AS4059 rev E Table

73The Navy Standard for Hydraulic Fluids used for aircraft hydraulic systems is de ned in the Aviation Hydraulics Manual (1989), Table 2-1, Navy Stan

Seite 76 - GOST 17216-2001 Table

74Percent contamination vs. PPM (parts per million)Percent PPM100% 1,000,00010% 100,0001% 10,0000.1% 1,0000.01% 1000.001% 10Volume1 litre = 1 000 ml1

Seite 77 - NAV AIR 10-1A-17 Table

The items described in this document and other documents and descriptions provided by Parker Hanni n Corporation, its subsidiaries and its authorized

Seite 78 - PPM Conversion Table

*Note: In compliance with international standards, all Parker portable particle counters can meet the ISO Medium test dust standards. The icountLCM’s,

Seite 79

Offer of SaleThe items described in this document and other documents and descriptions provided by Parker Hanni n Corporation, its subsidiaries and i

Seite 82

The Aerospace Group is a leader in the development, design, manufacture and servicing of control systems and components for aerospace and related high

Seite 83 - Parker Hannifi n Corporation

North AmericaCompressed Air TreatmentFiltration & Separation/BalstonHaverhill, MA978 858 0505www.parker.com/balstonFinite Airtek Filtration Airtek

Seite 84 - Latin America

icountLCM20Portable Particle CounterWhy On-Site Fluid Contamination Monitoring?Data Download ManagementDedicated software, provides the link between a

Kommentare zu diesen Handbüchern

Keine Kommentare